| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| In Odoo 8.0, Odoo Community Edition 9.0 and 10.0, and Odoo Enterprise Edition 9.0 and 10.0, remote attackers can bypass authentication under certain circumstances because parameters containing 0x00 characters are truncated before reaching the database layer. This occurs because Psycopg 2.x before 2.6.3 is used. |
| Weak access controls in the Device Logout functionality on the TP-Link TL-SG108E v1.0.0 allow remote attackers to call the logout functionality, triggering a denial of service condition. |
| Weak access control methods on the TP-Link TL-SG108E 1.0.0 allow any user on a NAT network with an authenticated administrator to access the device without entering user credentials. The authentication record is stored on the device; thus if an administrator authenticates from a NAT network, the authentication applies to the IP address of the NAT gateway, and any user behind that NAT gateway is also treated as authenticated. |
| The outdoor unit of Customer Premise Equipment (CPE) product B2338-168 V100R001C00 has a no authentication vulnerability on a certain port. After accessing the network between the indoor and outdoor units of the CPE, an attacker can deliver commands to the specific port of the outdoor unit and execute them without authentication. Successful exploit could allow the attacker to take control over the outdoor unit. |
| Incorrect access control in AMAG Symmetry Door Edge Network Controllers (EN-1DBC Boot App 23611 03.60 and STD App 23603 03.60; EN-2DBC Boot App 24451 01.00 and STD App 2461 01.00) enables remote attackers to execute door controller commands (e.g., lock, unlock, add ID card value) by sending unauthenticated requests to the affected devices via Serial over TCP/IP, as demonstrated by a Ud command. |
| A Missing Authentication for Critical Function issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 or prior, and InTouch Machine Edition v8.0 SP2 or prior. InduSoft Web Studio provides the capability for an HMI client to trigger script execution on the server for the purposes of performing customized calculations or actions. A remote malicious entity could bypass the server authentication and trigger the execution of an arbitrary command. The command is executed under high privileges and could lead to a complete compromise of the server. |
| rkhunter versions before 1.4.4 are vulnerable to file download over insecure channel when doing mirror update resulting into potential remote code execution. |
| A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack on the integrated web server on port 443/tcp. |
| Remote enabling and disabling admin interface in Gemalto's HASP SRM, Sentinel HASP and Sentinel LDK products prior to Sentinel LDK RTE version 7.55 leads to new attack vectors. |
| A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker with access to port 21/tcp to access or alter historical measurement data stored on the device. |
| A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2). The existing TLS protocol implementation could allow an attacker to read and modify data within a TLS session while performing a Man-in-the-Middle (MitM) attack. |
| WiMAX routers based on the MediaTek SDK (libmtk) that use a custom httpd plugin are vulnerable to an authentication bypass allowing a remote, unauthenticated attacker to gain administrator access to the device by performing an administrator password change on the device via a crafted POST request. |
| A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). An attacker who performs a Man-in-the-Middle attack between the LOGO! BM and other devices could potentially decrypt and modify network traffic. |
| A Missing Authentication for Critical Function issue was discovered in OPW Fuel Management Systems SiteSentinel Integra 100, SiteSentinel Integra 500, and SiteSentinel iSite ATG consoles with the following software versions: older than V175, V175-V189, V191-V195, and V16Q3.1. An attacker may create an application user account to gain administrative privileges. |
| A resource-permission flaw was found in the openstack-tripleo-heat-templates package where ceph.client.openstack.keyring is created as world-readable. A local attacker with access to the key could read or modify data on Ceph cluster pools for OpenStack as though the attacker were the OpenStack service, thus potentially reading or modifying data in an OpenStack Block Storage volume. |
| Crypto-NAK packets in ntpd in NTP 4.2.x before 4.2.8p4, and 4.3.x before 4.3.77 allows remote attackers to bypass authentication. |
| When the device is configured to perform account lockout with a defined period of time, any unauthenticated user attempting to log in as root with an incorrect password can trigger a lockout of the root account. When an SRX Series device is in cluster mode, and a cluster sync or failover operation occurs, then there will be errors associated with synch or failover while the root account is locked out. Administrators can confirm if the root account is locked out via the following command root@device> show system login lockout user root User Lockout start Lockout end root 1995-01-01 01:00:01 PDT 1995-11-01 01:31:01 PDT Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D65 on SRX series; 12.3X48 prior to 12.3X48-D45 on SRX series; 15.1X49 prior to 15.1X49-D75 on SRX series. |
| The Erlang otp TLS server answers with different TLS alerts to different error types in the RSA PKCS #1 1.5 padding. This allows an attacker to decrypt content or sign messages with the server's private key (this is a variation of the Bleichenbacher attack). |
| Revive Adserver before 3.2.3 suffers from Improper Restriction of Excessive Authentication Attempts. The login page of Revive Adserver is vulnerable to password-guessing attacks. An account lockdown feature was considered, but rejected to avoid introducing service disruptions to regular users during such attacks. A random delay has instead been introduced as a countermeasure in case of password failures, along with a system to discourage parallel brute forcing. These systems will effectively allow the valid users to log in to the adserver, even while an attack is in progress. |
| ACTi cameras including the D, B, I, and E series using firmware version A1D-500-V6.11.31-AC fail to properly restrict access to the factory reset page. An unauthenticated, remote attacker can exploit this vulnerability by directly accessing the http://x.x.x.x/setup/setup_maintain_firmware-default.html page. This will allow an attacker to perform a factory reset on the device, leading to a denial of service condition or the ability to make use of default credentials (CVE-2017-3186). |