| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A hard-coded credentials issue was discovered on Mimosa Client Radios before 2.2.3, Mimosa Backhaul Radios before 2.2.3, and Mimosa Access Points before 2.2.3. These devices run Mosquitto, a lightweight message broker, to send information between devices. By using the vendor's hard-coded credentials to connect to the broker on any device (whether it be an AP, Client, or Backhaul model), an attacker can view all the messages being sent between the devices. If an attacker connects to an AP, the AP will leak information about any clients connected to it, including the serial numbers, which can be used to remotely factory reset the clients via a page in their web interface. |
| An Incorrect Password Management issue was discovered in SMA Solar Technology products. Default passwords exist that are rarely changed. User passwords will almost always be default. Installer passwords are expected to be default or similar across installations installed by the same company (but are sometimes changed). Hidden user accounts have (at least in some cases, though more research is required to test this for all hidden user accounts) a fixed password for all devices; it can never be changed by a user. Other vulnerabilities exist that allow an attacker to get the passwords of these hidden user accounts. NOTE: the vendor reports that it has no influence on the allocation of passwords, and that global hardcoded master passwords do not exist. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected |
| Green Packet DX-350 Firmware version v2.8.9.5-g1.4.8-atheeb has a default password of admin for the admin account. |
| An authentication bypass vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the system contains a hard-coded valid session. An attacker can use that session ID as part of the HTTP cookie of a web request, resulting in authentication bypass |
| A vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the web service contains a hidden system account with a hardcoded password. An attacker can use this information to log into the system with high-privilege credentials. |
| Trango ApexLynx 2.0, ApexOrion 2.0, GigaLynx 2.0, GigaOrion 2.0, and StrataLink 3.0 devices have a built-in, hidden root account, with a default password for which the MD5 hash value is public (but the cleartext value is perhaps not yet public). This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it. |
| Trango Altum AC600 devices have a built-in, hidden root account, with a default password of abcd1234. This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it. |
| Mutiny 7.2.0-10788 suffers from Hardcoded root password. |
| Common encryption key appears to be used across all deployed instances of Serv-U FTP Server. Because of this an encrypted value that is exposed to an attacker can be simply recovered to plaintext. |
| Ovarro TBox TWinSoft uses the custom hardcoded user “TWinSoft” with a hardcoded key. |
| Nokia Fastmile 3tg00118abad52 devices shipped by Optus are shipped with a default hardcoded admin account of admin:Nq+L5st7o This account can be used locally to access the web admin interface. |
| GE UR bootloader binary Version 7.00, 7.01 and 7.02 included unused hardcoded credentials. Additionally, a user with physical access to the UR IED can interrupt the boot sequence by rebooting the UR. |
| An attacker can gain VxWorks Shell after login due to hard-coded credentials on a KUKA KR C4 control software for versions prior to 8.7 or any product running KSS. |
| An issue was discovered in Elspec G5 digital fault recorder versions 1.1.4.15 and before. A hardcoded backdoor session ID exists that can be used for further access to the device, including reconfiguration tasks. |
| Sensitive endpoints in Fresenius Kabi Agilia Link+ v3.0 and prior can be accessed without any authentication information such as the session cookie. An attacker can send requests to sensitive endpoints as an unauthenticated user to perform critical actions or modify critical configuration parameters. |
| Vigilant Software Suite (Mastermed Dashboard) version 2.0.1.3 contains service credentials likely to be common across all instances. An attacker in possession of the password may gain privileges on all installations of this software. |
| The affected product has a hardcoded private key available inside the project folder, which may allow an attacker to achieve Web Server login and perform further actions. |
| Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) uses hard-coded credentials for its UltraVNC installation. Successful exploitation of this vulnerability could allow a remote authenticated attacker to take full remote control of the host operating system. |
| Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated attacker could pass their own encrypted password to the ISaGRAF 5 Runtime, which may result in information disclosure on the device. |
| By having access to the hard-coded cryptographic key for GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06, attackers would be able to intercept and decrypt encrypted traffic through an HTTPS connection. |