Search Results (55729 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-27839 2026-04-15 3.2 Low
operations/attestation/AttestationTask.kt in the Tangem SDK before 5.18.3 for Android has a logic flow in offline wallet attestation (genuineness check) that causes verification results to be disregarded during the first scan of a card. Exploitation may not have been possible.
CVE-2025-27940 1 Intel 1 Tdx Module 2026-04-15 4.1 Medium
Out-of-bounds read for some TDX Module before version tdx1.5 within Ring 0: Hypervisor may allow an information disclosure. Software side channel adversary with a privileged user combined with a high complexity attack may enable data exposure. This result may potentially occur via local access when attack requirements are present without special internal knowledge and requires no user interaction. The potential vulnerability may impact the confidentiality (high), integrity (none) and availability (none) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (none) impacts.
CVE-2025-2811 2026-04-15 5.7 Medium
A vulnerability was found in GL.iNet GL-A1300 Slate Plus, GL-AR300M16 Shadow, GL-AR300M Shadow, GL-AR750 Creta, GL-AR750S-EXT Slate, GL-AX1800 Flint, GL-AXT1800 Slate AX, GL-B1300 Convexa-B, GL-B3000 Marble, GL-BE3600 Slate 7, GL-E750, GL-E750V2 Mudi, GL-MT300N-V2 Mango, GL-MT1300 Beryl, GL-MT2500 Brume 2, GL-MT3000 Beryl AX, GL-MT6000 Flint 2, GL-SFT1200 Opal, GL-X300B Collie, GL-X750 Spitz, GL-X3000 Spitz AX, GL-XE300 Puli and GL-XE3000 Puli AX 4.x. It has been declared as problematic. This vulnerability affects unknown code of the component API. The manipulation leads to inefficient regular expression complexity. It is recommended to upgrade the affected component.
CVE-2025-2826 2026-04-15 2.6 Low
n affected platforms running Arista EOS, ACL policies may not be enforced. IPv4 ingress ACL, MAC ingress ACL, or IPv6 standard ingress ACL enabled on one or more ethernet or LAG interfaces may result in ACL policies not being enforced for ingress packets. This can cause incoming packets to incorrectly be allowed or denied. The two symptoms of this issue on the affected release and platform are: * Packets which should be permitted may be dropped and, * Packets which should be dropped may be permitted.
CVE-2025-2851 2026-04-15 8 High
A vulnerability classified as critical has been found in GL.iNet GL-A1300 Slate Plus, GL-AR300M16 Shadow, GL-AR300M Shadow, GL-AR750 Creta, GL-AR750S-EXT Slate, GL-AX1800 Flint, GL-AXT1800 Slate AX, GL-B1300 Convexa-B, GL-B3000 Marble, GL-BE3600 Slate 7, GL-E750, GL-E750V2 Mudi, GL-MT300N-V2 Mango, GL-MT1300 Beryl, GL-MT2500 Brume 2, GL-MT3000 Beryl AX, GL-MT6000 Flint 2, GL-SFT1200 Opal, GL-X300B Collie, GL-X750 Spitz, GL-X3000 Spitz AX, GL-XE300 Puli and GL-XE3000 Puli AX 4.x. Affected is an unknown function of the file plugins.so of the component RPC Handler. The manipulation leads to buffer overflow. It is recommended to upgrade the affected component.
CVE-2025-30742 2026-04-15 5.3 Medium
httpd.c in atophttpd 2.8.0 has an off-by-one error and resultant out-of-bounds read because a certain 1024-character req string would not have a final '\0' character.
CVE-2025-31929 2026-04-15 4.2 Medium
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions), UL Resi High End 40A w/15118 Hw (8EM1312-4CF18-0FA3) (All versions), UL Resi High End 48A w/15118 Hw (8EM1312-5CF18-0FA3) (All versions), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions). Affected devices do not contain an Immutable Root of Trust in M0 Hardware. An attacker with physical access to the device could use this to execute arbitrary code.
CVE-2025-31930 2026-04-15 8.8 High
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.
CVE-2025-3194 2026-04-15 7.5 High
Versions of the package bigint-buffer from 0.0.0 are vulnerable to Buffer Overflow in the toBigIntLE() function. Attackers can exploit this to crash the application.
CVE-2025-3197 2026-04-15 7.3 High
Versions of the package expand-object from 0.0.0 are vulnerable to Prototype Pollution in the expand() function in index.js. This function expands the given string into an object and allows a nested property to be set without checking the provided keys for sensitive properties like __proto__.
CVE-2025-32007 1 Intel 1 Tdx Module 2026-04-15 4.4 Medium
Out-of-bounds read for some TDX before version tdx module 1.5.24 within Ring 0: Hypervisor may allow an information disclosure. Authorized adversary with a privileged user combined with a low complexity attack may enable data exposure. This result may potentially occur via local access when attack requirements are present without special internal knowledge and requires no user interaction. The potential vulnerability may impact the confidentiality (high), integrity (none) and availability (none) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (none) impacts.
CVE-2025-32014 2026-04-15 N/A
estree-util-value-to-estree converts a JavaScript value to an ESTree expression. When generating an ESTree from a value with a property named __proto__, valueToEstree would generate an object that specifies a prototype instead. This vulnerability is fixed in 3.3.3.
CVE-2025-32029 2026-04-15 N/A
ts-asn1-der is a collection of utility classes to encode ASN.1 data following DER rule. Incorrect number DER encoding can lead to denial on service for absolute values in the range 2**31 -- 2**32 - 1. The arithmetic in the numBitLen didn't take into account that values in this range could result in a negative result upon applying the >> operator, leading to an infinite loop. The issue is patched in version 1.0.4. If upgrading is not an option, the issue can be mitigated by validating inputs to Asn1Integer to ensure that they are not smaller than -2**31 + 1 and no larger than 2**31 - 1.
CVE-2025-32033 2026-04-15 7.5 High
The Apollo Router Core is a configurable, high-performance graph router written in Rust to run a federated supergraph that uses Apollo Federation 2. Prior to 1.61.2 and 2.1.1, the operation limits plugin uses unsigned 32-bit integers to track limit counters (e.g. for a query's height). If a counter exceeded the maximum value for this data type (4,294,967,295), it wrapped around to 0, unintentionally allowing queries to bypass configured thresholds. This could occur for large queries if the payload limit were sufficiently increased, but could also occur for small queries with deeply nested and reused named fragments. This has been remediated in apollo-router versions 1.61.2 and 2.1.1.
CVE-2025-32056 1 Bosch 1 Infotainment System Ecu 2026-04-15 4 Medium
The anti-theft protection mechanism can be bypassed by attackers due to weak response generation algorithms for the head unit. It is possible to reveal all 32 corresponding responses by sniffing CAN traffic or by pre-calculating the values, which allow to bypass the protection. First identified on Nissan Leaf ZE1 manufactured in 2020.
CVE-2025-32901 1 Kde 1 Kdeconnect 2026-04-15 4.3 Medium
In KDE Connect before 1.33.0 on Android, malicious device IDs (sent via broadcast UDP) could cause an application crash.
CVE-2025-32061 1 Bosch 1 Infotainment System Ecu 2026-04-15 8.8 High
The specific flaw exists within the Bluetooth stack developed by Alps Alpine of the Infotainment ECU manufactured by Bosch. The issue results from the lack of proper boundary validation of user-supplied data, which can result in a stack-based buffer overflow when receiving a specific packet on the established upper layer L2CAP channel. An attacker can leverage this vulnerability to obtain remote code execution on the Infotainment ECU with root privileges. First identified on Nissan Leaf ZE1 manufactured in 2020.
CVE-2025-32062 1 Bosch 1 Infotainment System Ecu 2026-04-15 8.8 High
The specific flaw exists within the Bluetooth stack developed by Alps Alpine of the Infotainment ECU manufactured by Bosch. The issue results from the lack of proper boundary validation of user-supplied data, which can result in a stack-based buffer overflow when receiving a specific packet on the established upper layer L2CAP channel. An attacker can leverage this vulnerability to obtain remote code execution on the Infotainment ECU with root privileges. First identified on Nissan Leaf ZE1 manufactured in 2020.
CVE-2025-32072 2026-04-15 N/A
Improper Encoding or Escaping of Output vulnerability in The Wikimedia Foundation Mediawiki Core - Feed Utils allows WebView Injection.This issue affects Mediawiki Core - Feed Utils: from 1.39 through 1.43.
CVE-2025-32074 2026-04-15 5.4 Medium
Improper Encoding or Escaping of Output vulnerability in The Wikimedia Foundation Mediawiki - Confirm Account Extension allows Cross-Site Scripting (XSS).This issue affects Mediawiki - Confirm Account Extension: from 1.39 through 1.43.